Can the indicator light on the mobile phone jammer shell feedback the real working status?
Examination room-type mobile phone jammers
configured in some standardized examination room projects now often put forward
some special requirements for the appearance of the shielding device, including
one: a working status indicator light needs to be configured on the device
shell, and the device needs to be The different frequency bands in the tester
have working indicator lights as one-to-one correspondence to feedback the real
working status of this test room-type shielding device. Then the question arises:
Is it necessary to install many working indicator lights on the casing of the
mobile phone jammer installed and used in the standardized examination room?
Can these indicator lights feed back the real working status?
The reason why such a requirement is put
forward in some projects is that it is actually an exclusive option used by
some test room mobile phone jammer manufacturers to control the number of
bidding codes or exclude other similar products. It is an attempt to create
some exclusive technical indicators through the appearance of the device or
individual small functional differences. Although these products are clearly
marked with status indicators with more than ten power frequency bands, it is
not difficult to find the problem as long as they are carefully tested and
functionally verified. For example: For example, the most common mobile phone
jammer in the examination room with 5G signal shielding function is usually
equipped with 12 signal shielding modules. Normally, there are 12 status indicators
corresponding to it. In addition, it should It also includes at least one power
indicator light indicating whether the host power supply is powered on or not.
Then let's distinguish carefully, what are the functions of these 13 indicator
lights? The first is the power-on indicator of the host power supply, which is
not difficult to understand. When the switch of the mobile phone jammer is
turned on and the device receives power, the host power indicator is always on.
What information is fed back by the remaining 12 indicator lights? When all
these indicator lights are on, does it mean that all the 12 signal shielding
modules are working normally? The real result is disappointing, because some
manufacturers may just connect these 12 indicator lights to the power supply
indicators of the modules. When these lights are lit, it just means that each
module has received effective power supply. In fact, it does not represent
whether each module is working normally. For example, some modules are indeed
powered, but in fact their signal source or power amplifier has failed. The
module actually does not shield the signal from being emitted, but, Since the
indicator light is still on, the customer cannot know the real fault
information of each module in the shielding device.
In fact, we don't advocate that the mobile
phone jammers in the examination room should be equipped with more function
indicators. There are two reasons: the first reason is that too many indicator
lights can not really represent the failure of each module in the device. ,
unless it is a circuit for fault detection and analysis for each signal
shielding module, and the indicator light is wired out from the detection
circuit. The second reason is that the mobile phone jammer is installed in the
classroom of the examination room. It is one of the supporting protection
products for the standardized examination room. It is not appropriate to make
these supporting products too conspicuous. If there are many lights on a
shielding device during the examination Flickering or flickering frequently due
to faults, which will attract the attention of candidates and distract
students.